Search
Close this search box.

LAS OEM Sensors

Our technology - Your brand

We don’t have to put our name on it!

Instead we offer OEM solutions with our top-notch gas analysis technology for your product. We are happy to compliment your product solution with our know-how to create the best value for your customer. Wether we are extending your product functions or making it safer with e.g. continuous emission monitoring. We look forward to working with you!

long-term stability, high accuracy

LAS OEM-Sensors

LAS-OEM Modules belong to the most accurate measuring methods for trace gas analysis for all industrial and process gases (e.g. VHP/vapourized hydrogen preoxide) into the ppt range. The determination of different gases in one measuring process is possible. Due to long-range cells and focused laser beams, only a small sample volume is required.

Examples of customer-specific projects using LAS technology

Here you can have a look at our previously developed analyzers in the LAS technology area. Please do not hesitate to contact us, even if your application is not listed. We develop individually based on your requirements!

LAS Sensor

Laserabsorptionspectroscopy sensor, OEM Sensor Laserabsorptionsspektriskopie
Laserabsorptionspectroscopy sensor, OEM Sensor Laserabsorptionsspektriskopie

LASmini Sensor

LAS sensor, hot measurement, OEM-Sensor, Laserabsorptionsspectroscopy
LAS sensor, hot measurement, OEM-Sensor, Laserabsorptionsspectroscopy

Technical Data

Technical dataLASLASmini hot
Ambient temperature10 - 35 °C (non condensing)
Gas temperatureup to 35 °Cup to 190 °C
Gas flow< 2,0 l/min(1)
CommunicationCAN + Modbus TCP/IP + analog output 4 - 20 mA (optional)
Dimensions (L x W x H)543 x 236 x 185 mm372 x 255 x 160 mm
Weight14 kg6 kg
Power supply24 V DC
1 depends on required pressure and pump

Specifications

SpecificationsLASLASmini hot
Gas (other gases on demand)H2O2NH3
Measuring range (FS)10 - 1.000 ppm0 - 1.000 ppm
Limit of detection (LOD)2 < 50 ppb (3σ) t90-t10 ≤ 30 s @ 1.000 ppm< 0,1 ppm (2σ@t10-t90 ≤ 2 s)
Linearity≤ ± 0,5 ppm or ± 1 % of measured value≤ ± 1 ppm oder ± 1 % of measured value
Zero drift≤ 50 ppb in 8 h≤ ± 0,15 ppm in 8 h
Span drift≤ ± 1 % FS in 8 h≤ ± 0,5 % FS in 8 h
1 increased ranges on demand
2 optional < 5 ppb (2σ)

Need help?

Let us help you choose the perfect gas analyzer technology for your needs. We develop customized gas analyzers or OEM sensors according to your specifications. Simply talk to us about your desired application!